Official distributor in Vietnam

Genuine SYKAM in Vietnam

Sykam GmbH is a German company that, thanks to its expertise in manufacturing and development processes for chromatography equipment and compliance with international standards such as ISO 9001 and 13485, has been one…

Hoa Viet imports & distributes directly from Sykam

We would like to introduce information about Sykam

Sykam GmbH is a German company that, thanks to its expertise in manufacturing and development processes for chromatography equipment and compliance with international standards such as ISO 9001 and 13485, has been one of the world's leading suppliers of Amino Acid Analyzers (AAA) since 1980. In addition, Sykam chromatography systems also include Ion Chromatography, Preparative Chromatography, and HPLC.

Certificate of Hoa Viet as an authorized distributor of SYKAM
SYKAM distributor certificate

A Sykam exclusive strength

Only 2 buffer solutions to run 18 amino acids

2buffer solutions
18amino acids (AA)

Currently, only the Sykam amino acid analyzer can run 18 AA with just 2 buffer solutions. This is a key advantage of Sykam over other brands: it saves chemicals and helps customers better manage the chemicals used to operate the instrument.

Note
  • 3 buffer solutions for 20 AA as stated in the Sykam documentation meets the standard instrument acceptance conditions. The 23 AA figure is based on actual test runs and acceptance testing at 2 international testing laboratories in Vietnam.
  • Hoa Viet is ready to share the SOP so customers can prepare the buffer solutions for the AAA instrument themselves.
Model S 433 · Made in Germany

Sykam S 433 Automatic Amino Acid Analyzer

The Sykam S 433 is a dedicated ion-exchange chromatography system for the separation and quantification of amino acids: separation on a high-performance cation-exchange column, post-column derivatization with ninhydrin and simultaneous detection at 570 nm and 440 nm. It combines the proven reliability of classical ion-exchange chromatography with the advantages of modern high-performance liquid chromatography (HPLC).

Cation-exchange separation with post-column ninhydrin derivatization fully complies with EU Commission Directive 98/64/EC and is the trusted standard for physiological fluids as well as food and feedstuff hydrolysates. Hoa Viet imports and distributes directly from Sykam GmbH (Germany).

  • 23common amino acids in a single injection
  • ≤ 0.3 %RSD retention time
  • ≤ 1.0 %RSD peak area
  • 120vials, cooled sample tray
Sykam S 433 amino acid analyzer: S 7130 reagent organizer, S 5200 autosampler, S 4300 reaction module and S 2100 pump

Principle: cation exchange and post-column ninhydrin derivatization

Samples are separated on a cation-exchange column with a buffer gradient; after the column the eluate is mixed with ninhydrin and passes a high-temperature reactor to form the coloured complex, which is measured by a dual-channel photometer. All parts in contact with buffers and reagents are made of inert materials (PEEK, PTFE, PVDF), so no special non-corrosive buffer compositions or reagents are needed.

  1. S 7130 · Reagent Organizer

    Reagent storage

    Buffers and ninhydrin are stored in a refrigerated cabinet under inert gas (N₂) pressure to avoid oxidation and air contamination.

  2. S 2100 · Solvent Delivery

    Quaternary gradient pump

    Dual-plunger pump with active pulse compensation for a stable baseline, integrated vacuum degasser, more than 100 gradient steps with 0.1 % resolution.

  3. S 5200 · Autosampler

    Automatic injection

    Cooled tray for 120 vials, 1–100 µL injection without sample loss, programmable wash against cross-contamination.

  4. S 4300 · Column oven

    Cation-exchange separation

    Column oven +20 to +99 °C with active heating and cooling, up to 12 temperature steps per program.

  5. S 4300 · Reactor & detector

    Ninhydrin + 2-channel photometer

    Reactor up to 180 °C (normally 130 °C), automatic coil flushing after each run; simultaneous 570 nm and 440 nm detection.

Flow diagram of the Sykam S 433 amino acid analyzer
S 433 flow diagram: S 7130 reagent organizer → S 2100 pump (degasser, mixer, buffer pump, ammonia washing column) → S 5200 autosampler → S 4300 module (column oven, reagent pump, reactor, 2-channel photometer). Source: Sykam brochure.

Multistep buffer gradient

Old step-elution systems needed 4–5 buffer solutions. With the optimized S 433 buffer system only 2 buffers for hydrolysates and 3 for physiological samples are needed; the buffers are mixed continuously to form the optimum profile at any part of the separation.

  • Na, Li or K buffer systems (2–4 buffers depending on method) with a flexible quaternary gradient.
  • The lithium buffer system runs hydrolysate and physiological programs without changing buffers or columns.
  • Ready-made buffers tested lot by lot, ready-made ninhydrin and standard solutions.
  • 440 nm for proline and 4-hydroxyproline, 570 nm for the other amino acids; optional summing of both channels for single-channel integration.
Gradient mixing versus classical step elution
Gradient mixing (S 433) versus classical step elution. Source: Sykam brochure.

S 433 system configuration

Standard configuration supplied by Hoa Viet, one unit per item.

ItemDescriptionKey specifications / benefits
Eluent delivery system (S 2100)Quaternary gradient pump with integrated vacuum degasserInert PEEK/PTFE fluidics (zero corrosion from acidic buffers); active pulse compensation for a stable baseline
Autosampler module (S 5200)Automated sample injection systemCooled sample tray up to 120 vials; 1–100 µL injection with zero sample loss
Post-column derivatization module (S 4300)High-temperature reaction coil and ninhydrin pumpProgrammable up to 180 °C, normally 130 °C; automatic capillary flushing
Dual-channel photometer (S 4300)Integrated wavelength detectorSimultaneous 440 nm (proline, 4-hydroxyproline) and 570 nm (other amino acids)
Reagent organizer (S 7130)Refrigerated compartment for buffers and ninhydrinKept under inert gas (N₂) pressure to prevent ninhydrin oxidation
Separation column kitHigh-performance cation-exchange columnSpecialized resin for single-injection separation of 23 common amino acids (incl. tryptophan)
Chromatography softwareClarity / Sykam Data SystemFull instrument control, automatic peak integration, calibration and reporting
Consumables starter kitBuffers, ninhydrin reagents, vials, standard solutionsPre-formulated kit for immediate start-up, approx. 500–1,000 injections

Technical specifications

According to Sykam product specification PS-S433 (version 1.0) and the Sykam brochure.

MethodCation-exchange chromatography, post-column ninhydrin derivatization, detection at 570 nm and 440 nm
ApplicationsProtein hydrolysates, physiological fluids (serum/urine), biogenic amines
Method run times15–160 min depending on sample complexity and buffer system (plus regeneration time)
Retention time reproducibility≤ 0.3 % RSD
Peak area reproducibility≤ 1.0 % RSD
Baseline noise< ±25 µAU (ASTM)
Linearity0–2 AU (correlation factor > 0.999)
BuffersNa, Li or K; 2–4 buffers depending on method; quaternary gradient
S 2100 pumpDual-plunger pump, active pulse compensation; 0.01–10.00 mL/min (depending on pump head); max. 350 bar; more than 100 gradient steps, 0.1 % resolution; integrated vacuum degasser
Reagent pump2-plunger pump, 0.01–2.0 mL/min
Column oven+20 to +99 °C, active cooling, up to 12 temperature steps
ReactorAmbient to 180 °C (±1 °C); automatic coil flushing after each run
DetectorDual filter photometer 440/570 nm, constant signal output, signal summing, programmable offset, 3 rise times
S 5200 autosampler120 vials in cooled tray; sample compartment 5–70 °C; 1–100 µL in 1 µL steps; reproducibility < 1 % (10 µL); carry-over < 0.01 % depending on wash
S 7130 reagent organizerIntegrated cooling, inert gas (N₂) valves for oxygen-free storage, adjustable pressure (0.6–0.7 bar per configuration diagram)
SafetySystem pressure display; leakage sensors for reactor and column; high-pressure limit
Wetted materialsPEEK, PTFE, PVDF and other inert materials
SoftwareClarity Amino (DataApex Clarity CDS) / Sykam Data System; FDA 21 CFR Part 11 compliant

The pump and autosampler modules can also be used as a standard HPLC gradient pump and autosampler.

Applications and analysis programs

The S 433 is used for feedstuff, foodstuff, biogenic amines, pharmaceutical quality control and pharmacopoeia conformity. Standard Sykam programs:

ProgramSampleArginine elutes atInjection to injection
Standard hydrolysateProtein hydrolysates42 min58 min
Oxidized hydrolysateHydrolysates (cysteic acid, methionine sulfone)46 min59 min
Oxidized hydrolysate, lithium buffersHydrolysate and physiological without changing buffers/columns57 min77 min
Oxidized hydrolysate + 440 nm channelHydroxyproline, proline, additional β-alanine68 min88 min
Physiological routinePhysiological standard acidics/neutrals/basics103 min128 min
Extended physiologicalPlus pipecolic acid, homocitrulline, allo-isoleucine, kynurenine…158 min184 min
Short programArgininosuccinic acid, allo-isoleucine, homocystine…–44 min

Real chromatograms

Hydrolysate chromatogram on the Sykam S 433: amino acids and ammonia at 570 nm and 440 nm
Standard: hydrolysate amino acids (incl. hydroxyproline, tryptophan, hydroxylysine) and ammonia; arginine at 62.1 min. Background colours show the buffer gradient.
Oxidized hydrolysate standard chromatogram on the Sykam S 433 at 570 nm and 440 nm
Standard with cysteic acid, taurine, methionine sulfone and norleucine: 22 numbered peaks, arginine at 54.4 min.
Physiological standard chromatogram on the Sykam S 433
Physiological standard (acidics/neutrals/basics): arginine at 103 min. Source: Sykam brochure.
Pharmacopoeia requirements chromatogram for amino acid analysis on the Sykam S 433
Pharmacopoeia requirements: resolution Gly–Ala 2.040 (≥ 1.5), Cys–Met 3.867 (≥ 2.0), Ile–Leu 1.787 (≥ 1.5), Leu–Tyr 3.118 (≥ 2.0), Tyr–Phe 3.396 (≥ 2.0); symmetry Arg 1.276 (0.8–1.5). Source: Sykam brochure.

Clarity Amino software and GxP compliance

  • Based on the DataApex Clarity chromatography data station, FDA 21 CFR Part 11 compliant for GxP-regulated laboratories.
  • All method parameters are stored within the chromatogram file: buffer gradient, column temperature program, integration and calculation parameters, plus actual buffer and reagent pressure and column temperature recorded during the run.
  • The buffer gradient is visualized as background colours in the running chromatogram.
  • Full instrument control, automatic peak integration, calibration curves and reporting.
  • Users are free to use another CDS; the control software always stores all system parameters of the analysis.
Clarity Amino data acquisition screen on the Sykam S 433
Data acquisition screen with the buffer gradient as background colours. Source: Sykam brochure.

Order versions

Catalog no.Version
S001570Amino Acid Analyzer S 433 DS – Hydrolysates
S001638Amino Acid Analyzer S 433 DS – Physiological
S003098Amino Acid Analyzer S 433 DS – Biogenic Amines

Sykam S 433 FAQ

What principle does the Sykam S 433 use?

The Sykam S 433 separates amino acids on a cation-exchange column with a buffer gradient, then derivatizes them post-column with ninhydrin in a high-temperature reactor and detects simultaneously at 570 nm and 440 nm (proline and 4-hydroxyproline at 440 nm).

How long does a run take?

Method run times are 15–160 min depending on sample and buffer system, plus regeneration time. Example: standard hydrolysate program, arginine at 42 min, 58 min injection to injection.

How many buffers are needed?

With the optimized Sykam buffer system only 2 buffers are needed for hydrolysates and 3 for physiological samples; the lithium system runs both programs without changing buffers or columns.

Does the S 433 meet pharmacopoeia and GxP requirements?

The Sykam brochure shows chromatograms meeting pharmacopoeia resolution and symmetry criteria for amino acid analysis; Clarity Amino is FDA 21 CFR Part 11 compliant and the cation-exchange/post-column ninhydrin method complies with Directive 98/64/EC.

ISO 9001:2015 Certificate

SYKAM - Germany

ISO 13485:2016 Certificate

SYKAM - Germany - image 2

Contact us for information

Hoa Viet constantly strives to provide effective solutions for physicochemical and microbiological laboratories with top-quality products and services. We are committed to dedicated support to ensure customer satisfaction and maximum profitability.

SYKAM actual photos

Sykam S 433 amino acid analyzer installed in a customer laboratory, amino acid chromatogram in Clarity software
Hoa Viet booth - Sykam distributor in Vietnam - at an exhibition, showing Sykam chromatography systems
Sykam S 150 ion chromatography system and Sykam modules at the Hoa Viet booth